JEPA · 2026-11-16
Where to Predict in Retinal OCT? Anatomy-Guided Target Selection for I-JEPA
Yunchu Feng, Wai Tak Lau, Kaveri A. Thakoor
AI-assisted summary based on the paper. Consult the linked source for methods and limitations. Benchmark numbers appear after editor verification.
TL;DR
The authors study how to choose I-JEPA prediction target regions for retinal OCT, where retinal tissue occupies only part of each B-scan. Keeping the I-JEPA architecture and latent prediction objective, they compare uniform rectangular masking, anatomy-guided rectangular targets (using image intensity or MIRAGE segmentation), and more anatomically specific target shapes/coverage constraints. In FairVision glaucoma linear probing, image-intensity-guided rectangular targets achieve the highest AUC among the compared strategies.
Why it matters
I-JEPA’s uniform target placement can place many prediction regions on non-retinal background in retinal OCT. The paper tests whether guiding target selection using retinal anatomy or intensity improves learned representations, using linear probing for glaucoma classification on FairVision. The finding that simpler image-intensity guidance outperforms more detailed anatomical guidance (and that extra specificity does not consistently help) informs how to adapt predictive masking objectives to modality structure.
Method
- Pretrain image-based I-JEPA (ViT-Base, EMA target encoder) on retinal OCT B-scans and evaluate learned target-encoder features by linear probing for glaucoma classification on FairVision test volumes.
- Compare five masking families (random; centroid intensity-guided; envelope segmentation-guided rectangles; anatomy-shaped targets; coverage-constrained cover rectangles), changing only target placement/shape/context while keeping I-JEPA architecture and latent prediction objective.
- For each strategy, apply matched pretraining endpoints (epoch 50 as common) and report FairVision test AUC; also analyze delivered mask geometry (tissue hidden, purity, context).
Limitation
The authors note that FairVision has no retinal layer annotations, so neither guide can be scored for accuracy on it, and the evidence for anatomical guidance agreement is based on comparisons between two automatic guides (not anatomical accuracy).
Abstract (from arXiv)
Self-supervised learning aims to learn meaningful representations from unlabeled data, potentially allowing models to capture subtle anatomical variations across patients and reduce the amount of labeled data needed. Image-based Joint-Embedding Predictive Architecture (I-JEPA) learns by predicting target-region representations from visible context rather than reconstructing pixels. However, its uniform target placement does not account for the anatomical structure of retinal OCT, where retinal tissue occupies only part of each B-scan. We investigate anatomy-guided target selection using image intensity and predicted retinal segmentation while retaining the I-JEPA architecture and latent prediction objective. We compare anatomy-guided rectangular targets, anatomy-shaped targets and coverage-constrained placement with uniform masking, and evaluate the learned representations using linear probing for glaucoma classification on FairVision. We found that rectangular targets guided by image intensity achieved the highest linear-probe AUC in our comparisons. We show that anatomically meaningful target selection is promising for retinal OCT representation learning, while greater anatomical specificity did not consistently improve performance.
Related papers
- CI-JEPA: A Counterfactual Analysis of Latent Representations in Joint-Embedding Predictive Architectures for Self-Supervised Learning
- The Predictability Bias of Joint-Embedding Predictive Learning in Medical Imaging
- Self-Supervised Learning from Images with a Joint-Embedding Predictive Architecture
- AG-JEPA: Anatomically Guided Joint Embedding Predictive Architecture for Neurodegenerative Representation Learning
- Cracks in Embeddings: Robustness and Stability of JEPA-Based Chest X-Ray Representations
Publication record
Bibliographic evidence describes where and when a record appeared. It does not validate scientific claims.
First announced by arXiv: 2026-11-16 · Indexed by Pub-AI: 2026-11-16 UTC
Where to Predict in Retinal OCT? Anatomy-Guided Target Selection for I-JEPA
First announced by arXiv: 2026-11-16 · Original record ↗
- arxiv
- 2611.17586
Explicit source versions (1)
- v1 · Date not supplied
- Preprint available
Source date: 2026-11-16 · First detected: 2026-11-16 UTC · Historical baseline
Source evidence (1)
- Official evidence ↗ · RSS guid=oai:arXiv.org:2611.17586v1; arxiv:announce_type=new; item pubDate (official metadata)
Abstract · arxiv
Self-supervised learning aims to learn meaningful representations from unlabeled data, potentially allowing models to capture subtle anatomical variations across patients and reduce the amount of labeled data needed. Image-based Joint-Embedding Predictive Architecture (I-JEPA) learns by predicting target-region representations from visible context rather than reconstructing pixels. However, its uniform target placement does not account for the anatomical structure of retinal OCT, where retinal tissue occupies only part of each B-scan. We investigate anatomy-guided target selection using image intensity and predicted retinal segmentation while retaining the I-JEPA architecture and latent prediction objective. We compare anatomy-guided rectangular targets, anatomy-shaped targets and coverage-constrained placement with uniform masking, and evaluate the learned representations using linear probing for glaucoma classification on FairVision. We found that rectangular targets guided by image intensity achieved the highest linear-probe AUC in our comparisons. We show that anatomically meaningful target selection is promising for retinal OCT representation learning, while greater anatomical specificity did not consistently improve performance.