Cracks in Embeddings: Robustness and Stability of JEPA-Based Chest X-Ray Representations
Zahid Mansur, Kalpana Yadav, Deepak Mishra
AI-assisted summary based on the paper. Consult the linked source for methods and limitations. Benchmark numbers appear after editor verification.
TL;DR
The authors test four JEPA-based chest X-ray encoders (frozen) on black-box adversarial attacks (SPSA, Boundary), realistic corruptions (Gaussian noise, brightness, contrast), and a label-scarcity setting. They report severe model-dependent embedding and AUROC degradation by default, then show adversarial fine-tuning of the small predictor head (clean+perturbed) improves AUROC and embedding consistency, while a VQ codebook trained only on clean images degrades under distortion.
Why it matters
For medical imaging, representations may see scanner-specific changes and query-only attacks. The authors directly measure how JEPA chest X-ray encoders’ embeddings and classification AUROC shift under such perturbations, and study simple head-only remedies. This provides evidence that robustness is not guaranteed by JEPA pretraining or by adding a discrete bottleneck unless trained with perturbed data.
Method
- Freeze four JEPA-based chest X-ray encoders and attach a small residual predictor + linear classifier trained on clean NIH ChestX-ray14; evaluate on perturbed test images using embedding cosine similarity and Macro AUROC.
- Assess six tests: SPSA and Boundary black-box attacks, Gaussian noise/brightness/contrast corruptions, plus a few-sample (label-scarcity) evaluation.
- Train only the lightweight head to recover performance: adversarial fine-tuning (clean+perturbed) vs a vector-quantized codebook predictor trained on clean only.
Limitation
The authors test only black-box attacks (SPSA, Boundary) and evaluate robustness on perturbed test images; no established correction method beyond predictor/head training is described, and the codebook is trained on clean images only.
Abstract (from arXiv)
Self-supervised Joint Embedding Predictive Architecture (JEPA) models are increasingly used for medical imaging, however there is a limited understanding about robustness of these models toward real-world image changes. We test four JEPA-based chest X-ray encoders, trained on 78,468 NIH ChestX-ray14 images, under six tests: two black-box adversarial attacks (SPSA, Boundary Attack), three image corruptions (Gaussian noise, brightness shift, contrast shift), and a label-scarcity test, measuring embedding change and classification AUROC. These perturbations cause severe, model-dependent damage: encoder-level Cosine Similarity drops as low as 0.33, and AUROC falls by as much as 0.12 in the worst case (I-JEPA under the Boundary Test). We test two ways of training the small predictor on top of each frozen encoder to address this. Adversarial fine-tuning, trained on clean and perturbed images together, raises embedding consistency above 0.97 in nearly every case and improves AUROC, relative to the same perturbed baseline, for most models, with the largest gain of $+0.10$ on I-JEPA. A Vector-Quantized codebook method, trained only on clean images and evaluated on perturbed test images for the first time, instead degrades under distortion for all four models, most noticeably for I-JEPA ($-0.15$ AUROC on average), showing that its discrete bottleneck alone does not provide the robustness that comes from training on perturbed data directly.
Related papers
- JECT: Addressing the Context Shortcut in Joint-Embedding Predictive Learning for Chest CT
- The Predictability Bias of Joint-Embedding Predictive Learning in Medical Imaging
- CI-JEPA: A Counterfactual Analysis of Latent Representations in Joint-Embedding Predictive Architectures for Self-Supervised Learning
- MADJEPA: Enhanced Multi-Stage Joint-Embedding Predictive Architecture for Medical Anomaly Detection
- Self-Supervised Learning from Images with a Joint-Embedding Predictive Architecture
Publication record
Bibliographic evidence describes where and when a record appeared. It does not validate scientific claims.
First announced by arXiv: 2026-11-16 · Indexed by Pub-AI: 2026-11-16 UTC
Cracks in Embeddings: Robustness and Stability of JEPA-Based Chest X-Ray Representations
First announced by arXiv: 2026-11-16 · Original record ↗
- arxiv
- 2611.17905
Explicit source versions (1)
- v1 · Date not supplied
- Preprint available
Source date: 2026-11-16 · First detected: 2026-11-16 UTC · Historical baseline
Source evidence (1)
- Official evidence ↗ · RSS guid=oai:arXiv.org:2611.17905v1; arxiv:announce_type=new; item pubDate (official metadata)
Abstract · arxiv
Self-supervised Joint Embedding Predictive Architecture (JEPA) models are increasingly used for medical imaging, however there is a limited understanding about robustness of these models toward real-world image changes. We test four JEPA-based chest X-ray encoders, trained on 78,468 NIH ChestX-ray14 images, under six tests: two black-box adversarial attacks (SPSA, Boundary Attack), three image corruptions (Gaussian noise, brightness shift, contrast shift), and a label-scarcity test, measuring embedding change and classification AUROC. These perturbations cause severe, model-dependent damage: encoder-level Cosine Similarity drops as low as 0.33, and AUROC falls by as much as 0.12 in the worst case (I-JEPA under the Boundary Test). We test two ways of training the small predictor on top of each frozen encoder to address this. Adversarial fine-tuning, trained on clean and perturbed images together, raises embedding consistency above 0.97 in nearly every case and improves AUROC, relative to the same perturbed baseline, for most models, with the largest gain of $+0.10$ on I-JEPA. A Vector-Quantized codebook method, trained only on clean images and evaluated on perturbed test images for the first time, instead degrades under distortion for all four models, most noticeably for I-JEPA ($-0.15$ AUROC on average), showing that its discrete bottleneck alone does not provide the robustness that comes from training on perturbed data directly.