Driving · 2026-11-25

DiCT: Teaching X-ray Vision-Language Models to Reason via Imagining CT

Zhenghao Lu, Xiaotian Zhang, Songtao Jiang, Yiqun Lin, Siming Fu, Hualiang Wang, Zuozhu Liu

arXiv:2611.32344PDFCode

AI-assisted summary based on the paper. Consult the linked source for methods and limitations. Benchmark numbers appear after editor verification.

TL;DR

DiCT is a three-stage CT-to-X-ray reasoning transfer framework that trains an X-ray VLM to reason with CT-informed 3D knowledge without explicit CT reconstruction at inference. It uses structured SFT to separate “Thinking with X-ray” and “Thinking with CT”, CT-guided on-policy distillation for selective teacher guidance, and clinical GRPO to adapt from DRRs to real X-rays. The authors report improved 3D-RAD performance and lower inference FLOPs than CT reconstruction pipelines.

Why it matters

The authors target a key limitation of 2D X-rays for 3D anatomical reasoning by transferring CT-informed reasoning directly, enabling X-ray-only inference. This addresses the added compute and potential error propagation of reconstruction-based CT-from-X-ray pipelines, while aiming to preserve X-ray observations during distillation despite teacher-student asymmetry.

Method

  • Instruct the dreamer: structured SFT that formats outputs into “Thinking with X-ray”, “Thinking with CT”, and “Answer”, initializing CT-oriented reasoning while using only X-rays as visual input.
  • Visualize the dream: CT-guided on-policy distillation where a frozen CT teacher provides token-level guidance selectively to CT-oriented reasoning and answers, while regularizing X-ray reasoning toward the SFT reference.
  • Manifest the dream: adapt from DRRs to real clinical X-rays using clinical GRPO with task rewards and KL regularization to the OPD checkpoint.
Abstract (from arXiv)

Diagnosing with X-rays often requires reasoning about the 3D locations of abnormalities and their spatial relationships to surrounding anatomical structures, yet such reasoning remains challenging due to the loss of spatial information in 2D projections. To address this challenge, we propose Dreaming in CT (DiCT), a three-stage progressive CT-to-X-ray reasoning transfer framework that leverages a CT vision-language model (VLM) to guide an X-ray VLM. Through this CT-guided transfer, the student acquires CT-informed 3D reasoning capabilities, enabling it to reason directly from 2D X-rays without explicit CT reconstruction at inference time. The framework begins with instruct the dreamer, which equips the X-ray student with initial CT-oriented reasoning capabilities and establishes a structured interface that distinguishes X-ray observations from CT imagination. Building on this structure, visualize the dream introduces CT-guided on-policy distillation (OPD), where the CT teacher selectively guides the X-ray student's reasoning trajectories to transfer 3D anatomical knowledge. Finally, manifest the dream adapts the acquired reasoning capabilities from digitally reconstructed radiographs (DRRs) to real clinical X-rays. Experiments across two VLM backbones on 3D-RAD and ReXVQA demonstrate DiCT's effectiveness across radiological reasoning tasks, achieving a 1.66 percentage point improvement over a CT reconstruction-based baseline on 3D-RAD Abnormality Identification with 12.77$\times$ lower inference computation. Our code is available at https://github.com/HongYep/DiCT.

Related papers

Publication record

Bibliographic evidence describes where and when a record appeared. It does not validate scientific claims.

First announced by arXiv: 2026-11-25 · Indexed by Pub-AI: 2026-11-25 UTC

preprint

DiCT: Teaching X-ray Vision-Language Models to Reason via Imagining CT

Zhenghao Lu, Xiaotian Zhang, Songtao Jiang, Yiqun Lin, Siming Fu, Hualiang Wang, Zuozhu Liu

First announced by arXiv: 2026-11-25 · Original record ↗

arxiv
2611.32344
Explicit source versions (1)
  • v1 · Date not supplied
  1. Preprint available

    Source date: 2026-11-25 · First detected: 2026-11-25 UTC · Historical baseline

    Source evidence (1)
    • Official evidence ↗ · RSS guid=oai:arXiv.org:2611.32344v1; arxiv:announce_type=new; item pubDate (official metadata)
Abstract · arxiv

Diagnosing with X-rays often requires reasoning about the 3D locations of abnormalities and their spatial relationships to surrounding anatomical structures, yet such reasoning remains challenging due to the loss of spatial information in 2D projections. To address this challenge, we propose Dreaming in CT (DiCT), a three-stage progressive CT-to-X-ray reasoning transfer framework that leverages a CT vision-language model (VLM) to guide an X-ray VLM. Through this CT-guided transfer, the student acquires CT-informed 3D reasoning capabilities, enabling it to reason directly from 2D X-rays without explicit CT reconstruction at inference time. The framework begins with instruct the dreamer, which equips the X-ray student with initial CT-oriented reasoning capabilities and establishes a structured interface that distinguishes X-ray observations from CT imagination. Building on this structure, visualize the dream introduces CT-guided on-policy distillation (OPD), where the CT teacher selectively guides the X-ray student's reasoning trajectories to transfer 3D anatomical knowledge. Finally, manifest the dream adapts the acquired reasoning capabilities from digitally reconstructed radiographs (DRRs) to real clinical X-rays. Experiments across two VLM backbones on 3D-RAD and ReXVQA demonstrate DiCT's effectiveness across radiological reasoning tasks, achieving a 1.66 percentage point improvement over a CT reconstruction-based baseline on 3D-RAD Abnormality Identification with 12.77$\times$ lower inference computation. Our code is available at https://github.com/HongYep/DiCT.