JEPA · 2026-11-17
SLICES: A Benchmark and Evaluation Framework for Self-Supervised Learning on Sparse ICU Time Series
Hannes Ill, Dimitrios Proios, Leo Anthony Celi, Peter J. Sch\"uffler
AI-assisted summary based on the paper. Consult the linked source for methods and limitations. Benchmark numbers appear after editor verification.
TL;DR
SLICES is a benchmark/evaluation framework to compare self-supervised learning on sparse ICU time series under a shared clinical setup. It fixes a 24-hour value+observation-mask input, a small Transformer encoder, patient-level splits, four endpoints, two adaptation protocols (frozen linear probing and full fine-tuning), and matched seeds across MIMIC-IV, eICU-CRD, and their pooled union. Using fixed reference objectives (MAE, JEPA, contrastive), the authors report MAE leads mean AUPRC in all nine frozen classification comparisons and in seven of nine fine-tuning comparisons.
Why it matters
The authors argue ICU SSL results are hard to compare because data processing, encoders, and adaptation vary together. SLICES standardizes the clinical input contract, evaluation protocols, and endpoints so comparisons across SSL objectives and across reduced-label settings can be made under controlled conditions, with a repository that supports regeneration and extension.
Method
- Defines a fixed sparse-ICU interface (first 24 ICU hours as normalized values + observation masks), shared small Transformer encoder, patient-level splits, four endpoints, and two adaptation protocols: frozen probing and full fine-tuning.
- Implements reference self-supervised objectives (MAE, JEPA, contrastive learning) using the shared input/encoder transfer interface and common downstream evaluation heads.
- Provides a code repository and validators/audits to regenerate tables/figures from archived runs and to evaluate new SSL objectives under the same downstream protocols.
Limitation
Generalization to unseen hospitals is not tested here and is presented as the natural next extension.
Abstract (from arXiv)
Self-supervised learning (SSL) results for intensive care unit (ICU) time series are hard to compare when data processing, encoders, and adaptation vary together. We present SLICES, a benchmark and evaluation framework for comparing and extending SSL methods under a shared clinical setup. It fixes 24-hour value and observation-mask inputs, a Transformer encoder, patient-level splits, four endpoints, two adaptation protocols, and five matched seeds across MIMIC-IV, eICU-CRD, and their pooled union. Masked autoencoding (MAE), joint-embedding prediction (JEPA), and contrastive learning provide reference implementations. Among these objectives, MAE leads mean AUPRC in all nine frozen classification comparisons, also under converged probes, and in seven of nine fine-tuning comparisons. Fine-tuned MAE leads hospital mortality at full labels and scores higher than a supervised Transformer of the same architecture at every label fraction, and SSL fine-tuning gives the lowest length-of-stay error. Supervised baselines remain strong elsewhere: GRU-D leads 24-hour mortality and XGBoost leads acute kidney injury in all three regimes. Rankings depend on the adaptation protocol, the comparator set, and whether the probe loss matches the metric. A two-seed MIMIC-IV rerun with the maintained code stays within two across-seed SDs of the reference in all 48 downstream runs. The code repository supports new objectives, shared downstream evaluation, and regeneration of the reference results, so new SSL methods can be compared with these references under the same conditions. Generalization to unseen hospitals is not tested here and is the natural next extension.
Related papers
- Learning a patient world model for health system simulation in intensive care
- Phenomenon-Graph JEPA: Label-Efficient Representation Learning for Contactless Cardiorespiratory Sensing
- PatientWM: Towards Generalizable Clinical World Models via Unified Patient States
- Forecasting Patient Trajectories from the Electronic Health Records with Action-Conditioned World Models
- Are Joint-Embedding Predictive Objectives Effective for Longitudinal EHRs?
Publication record
Bibliographic evidence describes where and when a record appeared. It does not validate scientific claims.
First announced by arXiv: 2026-11-17 · Indexed by Pub-AI: 2026-11-17 UTC
SLICES: A Benchmark and Evaluation Framework for Self-Supervised Learning on Sparse ICU Time Series
First announced by arXiv: 2026-11-17 · Original record ↗
- arxiv
- 2611.18868
Explicit source versions (1)
- v1 · Date not supplied
- Preprint available
Source date: 2026-11-17 · First detected: 2026-11-17 UTC · Historical baseline
Source evidence (1)
- Official evidence ↗ · RSS guid=oai:arXiv.org:2611.18868v1; arxiv:announce_type=new; item pubDate (official metadata)
Abstract · arxiv
Self-supervised learning (SSL) results for intensive care unit (ICU) time series are hard to compare when data processing, encoders, and adaptation vary together. We present SLICES, a benchmark and evaluation framework for comparing and extending SSL methods under a shared clinical setup. It fixes 24-hour value and observation-mask inputs, a Transformer encoder, patient-level splits, four endpoints, two adaptation protocols, and five matched seeds across MIMIC-IV, eICU-CRD, and their pooled union. Masked autoencoding (MAE), joint-embedding prediction (JEPA), and contrastive learning provide reference implementations. Among these objectives, MAE leads mean AUPRC in all nine frozen classification comparisons, also under converged probes, and in seven of nine fine-tuning comparisons. Fine-tuned MAE leads hospital mortality at full labels and scores higher than a supervised Transformer of the same architecture at every label fraction, and SSL fine-tuning gives the lowest length-of-stay error. Supervised baselines remain strong elsewhere: GRU-D leads 24-hour mortality and XGBoost leads acute kidney injury in all three regimes. Rankings depend on the adaptation protocol, the comparator set, and whether the probe loss matches the metric. A two-seed MIMIC-IV rerun with the maintained code stays within two across-seed SDs of the reference in all 48 downstream runs. The code repository supports new objectives, shared downstream evaluation, and regeneration of the reference results, so new SSL methods can be compared with these references under the same conditions. Generalization to unseen hospitals is not tested here and is the natural next extension.